Study between Fracture Fixation of Patella with Cerclage and Tension Band Wiring Technique

Authors

  • Aakash Sharma1 , Nitin Samal2 , Kunal Saoji3 , Vasant Gawande4

DOI:

https://doi.org/10.37506/ijfmt.v14i4.12572

Keywords:

Patella fracture, Cerclage wiring, Tension band wiring

Abstract

Introduction: In human body among the skeletal system patella is the largest sesamoid bone in the
quadriceps tendon in the body. Surgery is required for about one third of patella facture that indicated
damage to the extensor mechanism. Regarding treatment of patellar fracture there is a controversy since
earliest time. TBW is consider as current gold standard for the displaced transverse patella fractures whereas
some surgeons recommend augmentation of TBW with circumferential cerclage wiring to enhance the
strength of the fixation.
Aim: The main aim was study between fracture fixation of patella with cerclage and Tension Band Wiring
technique.
Material and Method: Total 62 patients with fracture of patella were included in this study with the age
more than 20 years. Almost for all the patients surgery was performed and tourniquet was also used. By
using a midline longitudinal incision surgery was done over anterior aspect of the knee. By using tension
band wiring with or without augmented cerclage with stainless steel wire open reduction and internal fixation
were done. After the surgery as post operative knee brace was given so that patients could start range of
motion at knee without pain. To make sure that whether proper fixation was done or not Post-operative
radiographs were also done.
Result: In study total 50 patients were included in which 34(68%) were male and 16(32%) were female.
Among 50 patients was included different age group in which more patients were in the age group of 40-50
years old as 36%.
Conclusion: In the facture of patella modified TBW was better than encirclage wiring in treatment probably
because of good stability of implant and easier postoperative rehabilitation. Hence use of circumferential
cerclage wiring along with tension band wiring for fractures of patella has no added advantage over fixation
with tension band wiring alone.

Author Biography

  • Aakash Sharma1 , Nitin Samal2 , Kunal Saoji3 , Vasant Gawande4

    1(MBBS Resident) Dept. of Orthopedics Jawaharlal Nehru Medical College, Datta Meghe Institute of Medical
    Sciences, Sawangi (Meghe), Wardha-442001, 2Professor Dept. of Orthopedics Jawaharlal Nehru Medical College,
    Datta Meghe Institute of Medical Sciences, Sawangi (Meghe), Wardha-442001, 3Assistant Professor Dept. of
    Orthopedics Datta Meghe Medical College Datta Meghe Institute of Medical Sciences, Nagpur-441110, 4
    Associate
    Professor Dept. of Orthopedics Jawaharlal Nehru Medical College, Datta Meghe Institute of Medical Sciences,
    Sawangi (Meghe), Wardha-442001.

Downloads

Published

2020-10-29

How to Cite

Study between Fracture Fixation of Patella with Cerclage and Tension Band Wiring Technique. (2020). Indian Journal of Forensic Medicine & Toxicology, 14(4), 6217-6221. https://doi.org/10.37506/ijfmt.v14i4.12572