Analyzing the Positional uncertainties in 3dcrt ca breast Patients with Free Breathing and Active Breath Coordinator Gating Immobilization Devices

Authors

  • Sarath s Nair1 , Meena Devi2 , Krishna Sharan3 , Jyothi nagesh4 , Shambhavi C5 , Sajeesh S Nair6

DOI:

https://doi.org/10.37506/ijphrd.v11i6.9920

Keywords:

ABC, CBCT, xvi, DIBH gating, 3DCRT

Abstract

Aim: The aim of this study is to rule out the difference in positional setup errors when using immobilization

device such as thermoplastic mould for free breathing and vacloc with ABC gating in ca breast patient

treating with 3DCRT technique.

Objective: The study is to compare the patient setup uncertainties using two different immobilization device,

one with standard thermoplastic mould and other with vacuum cushion with active breath control gating in

our clinical setup.

Methodology: fourteen patients with ca breast are taken for the study. seven patients are undergone

immobilization using standard thermoplastic moulding and remaining seven patients undergone, vacuum

cushion with active breath control DIBH (deep inspiration breath hold) gating. CT was taken and 3dcrt plan

were done according to the standard protocol. Prior to the treatment CBCT was taken, matching was done

in XVI with the reference images, to rule out any positional shifts. Positional Shifts on all 3 axes such x,

y, z is noted with rotational shift. Comparison were done on systematic error (?), random error (?), mean

displacement vector (R), mean setup error (M).

Result: immobilization device used by vacloc with DIBH ABC gating shows very less shifts in all direction,

especially longitudinal direction compared with mould one, which we are using routinely in our department.

Author Biography

  • Sarath s Nair1 , Meena Devi2 , Krishna Sharan3 , Jyothi nagesh4 , Shambhavi C5 , Sajeesh S Nair6

    1lecturer,3Professor, 4Senior Grade Lecturer, Dept. of Radiotherapy and Oncology, Kasturba Medical College

    manipal, 2Associate professor, Dept. of physics and applied science, Noorul Islam higher education, Kumara coil 5Assistant Professor, Dept. of Medical physics, School of Allied Health Sciences, Manipal,6medical physicist/RSO,

    Dept. of radiotherapy and oncology, General hospital Ernakulum

Downloads

Published

2020-06-25

How to Cite

Analyzing the Positional uncertainties in 3dcrt ca breast Patients with Free Breathing and Active Breath Coordinator Gating Immobilization Devices. (2020). Indian Journal of Public Health Research & Development, 11(6), 984-988. https://doi.org/10.37506/ijphrd.v11i6.9920